Description
Featuresl Three test functions are available: ACW, DCW, IR
l The large 128 * 64 Graphic LCD display
l With 7305 single grounding impedance tester connection standard 19 inch rack instrument
l Can be tested 100 online at the same time
l
Built-in 10 program memory,
each group of three test steps for program memory test
l Fast communications , baud rate is as high as 1960
l Fast discharge function, the tested on the electricity can be put out in 0.2 seconds, to ensure safety
l Post detection test, determine the test if is normal before the test function
l The front panel software input correction
l Date and time setting, correction time and the warning time can remind users
l
The built-in PLC Remote control interface
l Button lock
l Safety lock function
l Compact size, light weight
Specifications:
Type
Function Description
7142
AC/DC Withstand Voltage/Insulation Tester
Ac Withstand Voltage Test
Rated Output:5KV AC/20ma
Range
Resolution Unit
Degree Of Precision
Output Voltage KVAC
0-5.00
0.01
±(1.5% Of Setting+5V)
Output Frequency
50/60Hz Optional
±100ppm
Output Waveform
Sine Wave THP<2% Crest Factor
HI Limit Ma
0-20.00
0.01
±(1.5% Of Setting+2counts)
LO Limit Ma
0-9.999
0.001
±(1.5% Of Setting+2counts)
Insulation Resistance Test
1000V/1000M
The Output Voltage Setting
0.01-1.00KV Dc
0.01
±(1.5% Of Setting+2V)
Voltage Display
0.01-1.00KV Dc
0.01
±(1.5% Of Setting+1counts)
High Resistance Display
9999MΩ
±(2% Of Setting+2counts) In Voltage >500Vdc
±(5% Of Setting+2counts) In Voltage >500Vdc
HI Limit
0.1-99999MΩ(0=OFF)
1MΩ/Step
±(2% Of Setting+2counts) In Voltage >500Vdc
LO Limit
1-9999MΩ
1MΩ/Step
±(5% Of Setting+2counts) In Voltage >500Vdc
The Dc Withstand Voltage Test
Rated Output:6KV Dc/7.5ma
Output Voltage Kvdc
0-6.00
0.01
±(1.5% Of Setting+5V)
Even The Wave
<5%D 6kvadc/5ma Resistance Under Load
HI Limit Ma
0.00-7.5
0.01
±(1.5% Of Setting+2counts)
LO Limit Ma
0.00-1
0.01
±(1.5% Of Setting+2counts)
Voltage Regulation
±(1% Setting +5V) No Load To Full Load
Ramp Time Sec
0.1-999.9
0.1
±(0.1% Of +0.05Sec)
Test Time Sec
0,1.0-999.9
0.1
±(0.1% Of +0.05Sec)
Arc Detection
0-9Section:0=OFF
PLC Remote Control
Input:Test,Reset,Mermory1.2.3,Interlock
Output:Pass ,Fail, Processing, Reset-Out
Test Failure Alarm
Buzzer
Storage Group
10 Group, Step 3 In Each Group
Safety Lock Keyboard
Can Choose To "Lock" Or "Not Locked" Two Modes
LCD
128 * 64 LCD Screen
Corrected Mode
The Front Panel Software Correction
Input Characteristics
Single Phase 47-63Hz
115/230Vac±15%,
Optional,3.15A Insurance
Work Environment
0-40℃/20-80%RH
Dimension
280(W)*100(H)*380(D)
Weight
10KG
Note:
1.W
ill ship
to
USA
via
DHL or Fedex
(not for PO Box or APO or FPO), delivery time is about
7 days.
2. Will ship via
express mail service
to Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea, Thailand, Malaysia, Indonesia, Philippine and Singapore customers.
3. Customers from other countries pls contact us in advance to confirm different shipping charges before you order.