-40%
RCD LINE LOOP TESTER UT595 MEGOHMMETER MEGGER RESISTANCE IMPEDANCE TESTER
$ 248.66
- Description
- Size Guide
Description
Extend AutomationRCD LINE LOOP TESTER UT595 MEGOHMMETER MEGGER RESISTANCE IMPEDANCE TESTER
Only suitable for AC 220V power supply, not for AC 110V.
UT595 is a kind of comprehensive digital multifunctional electrical safety test instrument. The overall instrument adopts new design as well as large-scale integrated analogy circuits, digital circuits and microcomputer chip combination. It is mainly used to complete measurement of parameters including (RCD) electric leakage protector, loop circuit/line impedance, grounding continuity test, test insulation resistance, DC voltage, AC voltage and phase sequence judgment; it has more functions, higher accuracy and stable performance as well as it is reliable and convenient for operation. It is applicable to measuring (RCD) electric leakage protector, measuring insulation of various electrical equipment and grounding continuity test. UT593/UT595 is your ideal choice for maintenance, test and inspection on electric protector of various electrical equipment.
Specifications:
Functions
Range
Accuracy
Open circuit output voltage
250V
-0.1
500V
1000V
Short circuit current
2mA
Insulation Resistance Measurement
250V
0.01M ohm
0.05M ohm to 1000M ohm: 5%+5
0.1M ohm
1M ohm
500V
0.01M ohm
0.1M ohm
1M ohm
1000V
0.01M ohm
0.1M ohm
1M ohm
Grounding (Earthing) continuity measurement
Range
0.00 ohm-199 ohm;+-2%+5
0.00-2 ohm, testing current is more than 200mA
Line impedance
Applied voltage
195V-440V,Frequency: 45Hz-65Hz;
Testing current:20A
Range
0.01 ohm-2000 ohm: 5%+5;
PSC: 0KA-26KA.
Loop impedance
Applied voltage
195V-253V,Frequency: 45Hz-65Hz;
Testing current: 20A
Range
0.01 ohm-2000 ohm: 5%+5;
PFC: 0KA-26KA.
Loop impedance without tripping
Applied voltage
195V-253V,Frequency: 45Hz-65Hz;
Testing current: 20A
Range
1.00 ohm-2000 ohm: 5%+5;
PFC: 0KA-26KA.
Testing current
15mA
RCD measurement
Applied voltage
195V-253V,Frequency: 45Hz-65Hz;
Testing current
10mA,30mA,100mA,300mA,500mA
Accuracy of testing current
-0.1
Tripping time
0ms--2000ms, 1/2 delta n
0ms--300ms, I delta n General
0ms--500ms, I delta n Selective
0ms--300ms, 2I delta n Selective
0ms--40ms, 5I delta n
Accuracy of tripping timee
4.95
RAMP Slope RCD measurement
Test current range
10mA,30mA,100mA,300mA,500mA
Accuracy of test current
-0.1
Phase consequence measurement
Display:
As per the sequency: L1→ L2→ L3 foreward; L1→ L3→ L2 reserved.
Applied voltage
100V-440V,frequency: 45Hz-65Hz.
Voltage measurement
Range and frequency
Resolution: 1V
0V--440V/45Hz-60Hz
Accuracy
1.95
Special functions
AUTO half-wave test
√
RCD Coundown test
30 seconds
RCD half-wave test
√
RCD 0°& 180°measurement
√
Data storage
√
Back light
√
Power off automatically
√
Low voltage display
√
General
Power supply
1.5V battery x 8
LCD size
125mm x37mm
Color
red and grey
Weight
4kg
Meter size
210mm x 175mm x 90 mm
Accessories
Test leads(red,green, black), electrical lead,far-end test control lead, case.
Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods containing such items, we will not be putting them packing. Thank you for your support.
Payment:
We currently only accept payment through PayPal.
Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later.
Feedback:
We strive for positive Feedback on all transactions and nothing less than an overall Detail Seller Rating (DSR) of 5 STAR.If you are considering giving a neutral or negative Feedback or a low DSR. Do write to us and give us an opportunity to address your concerns firstly.We will leave the positive feedback when we got your positive feedback.
Delivery details:
We are not responsible for undeliverable address. We reserve the right to charge the shipping fee again for returned items due to wrong address.
Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.)
RETURN POLICY:
We offer 14 days return policy from the day you received your item under the following conditions All returns must be in the original non-damaged condition, including packaging, documentation, warranty cards, manuals and accessories or else it will not be accepted.
Original shipping & handling charges are not refundable.
Customer is responsible for shipping, shipping cost and proof of delivery on all returns. Please be sure that you return shipments are properly packed and fully insured. We are not responsible for returned packages if lost by shipper/carrier or got damaged buy carrier.
Shipping cost (to and from buyer) will be charged for any refused shipping delivery (include duties, taxes and customs fee if any).
TAX&VAT
Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it.
Contact us:
Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you. please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price. We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases.
Copyright 2018 Extend Automation. All rights reserved.